| ArGeTon®
system used on aluminium substructure with vertical 'T' support
rails;
Aluminium brackets are fixed with approved fasteners along the
horizontal axis of the support
wall, spaced as structurally necessary. In this regard, attention
must be paid to the design of fixed
and floating points according to BS 8118:Part 1: 1991
Vertical aluminium ‘T’ section support profiles are
inserted into the brackets (a special receiver jaw
enables exact adjustment). Once the support profile is aligned it
is fixed with blind rivets or screws.
The best results are achieved if the 'T' sections are pre-punched
to the tile grid.
The ArGeTon® tiles are
mounted on the substructure free of tension using self-tapping stainless
steel screws or aluminium hollow rivets, and held in place at four
points with proprietary clips. Tiling
of the façade is undertaken from the bottom of the panel
upwards.